Summary: Code of air conditioning of family expenses frequency conversion is a bit much, whats need not say, small make up go up first graph, hope everybody can look satisfy a craving, get arrives more skill.
Explain: When air conditioning movement occurs all right unusual and stop when machine, maintenance technician should press only of the remote controller " sensor switch " pushbutton, the indicator light on switch face plate can show relevant breakdown content (1) seeing a table, indoor machine (the 2) seeing a table, machine outdoor (3) seeing a table, the blank space in column of state of indicator light job states the lamp goes out.
1. Content of breakdown of air conditioning of frequency conversion of KFR-2601GW / BP and eliminate a method
2. 2 frequency conversion of KFR-2601 × reason of indoor engine trouble reachs air conditioning eliminate a method
3. 2 frequency conversion of KFR-2601 × reason of trouble of the engine outdoor reachs air conditioning eliminate a method
4. Content of breakdown of air conditioning of frequency conversion of KFR-2802GW / BP and eliminate a method
5. Air conditioning of frequency conversion of KFR-3001GW / BP
6. Air conditioning of frequency conversion of KFR-3002GW / BP
7. Air conditioning of frequency conversion of KFR-3066GW / BP
8. Air conditioning of frequency conversion of KFR-3501GW / BP
9. KFR-4001GW / ZBP sheds frequency conversion air conditioning continuously
Explain: Detect in movement when giving indoor engine trouble, breakdown content will show immediately go up in liquid crystal screen, after breakdown is eliminated, air conditioning can restore by oneself. Breakdown content of the last time is the record in memory, if want to reproduce breakdown content, can have undermentioned operation: (1) unplugs next air conditioning power supply cord, after awaiting 1 minute, insert again time;
(2) closes plane position to fall in remote control, run mode is set for refrigeration, temperature set is 20 ℃ , press room temperature next " ∧ " key, press again " moving / stops " key, admiral of screen of indoor machine liquid crystal can display malfunction code:
(3) unplugs after issueing power supply cord 1 minute, be inserted again time, switch on the mobile phone, air conditioning can move normally.
If want cleared E2PROM(report to be able to be brushed,can keep memory) medium breakdown content, can undertake as follows operating (the indication operation) that must have breakdown content first: (1) unplugs outlet of next air conditioning power supply cord, after awaiting 1 minute, insert time; (2) closes plane position to fall in remote control, run mode is set to make heat, set temperature is 16 ℃ , press room temperature next " ∨ " key, press again " moving / stops " key, buzzer is long after crying, breakdown content is deleted namely; (3) unplugs outlet of next power supply cord, wait 1 minute to be inserted again time, switch on the mobile phone, air conditioning can move normally.
10. Air conditioning of frequency conversion of KFR-28GW / BPx2
Explain: (When 1) short-circuits when sensor of the indoor, temperature outdoor or opening circuit, compressor quits movement. (2) is become overheat of IPN power module (be more than 100 % ) , pass electricity (be more than 28A) , short circuit (be more than 51A) and driving voltage too low (be less than 12. When the breakdown such as 5V) , electric machinery of the fan outside compressing unit room will quit movement. (3) is spent when compressor platoon air temperature tall (be more than 120 ℃ ) when, compressor will quit movement. (When the outdoor plane that 4) high above in the sky moves inputs electric current to be more than set to be worth, compressor falls frequency runs, if compress machine electric current to still rise, shut compressor (when refrigeration, electric current of double machine set is 14A, when electric current is more than or be equal to 17A, compressor will stop turn) . (5) is expressed 14 in, blank space (point to indicator light condition) express insusceptible.
11. Air conditioning of form of cabinet of KFR-50LW/BP frequency conversion
12. Air conditioning of frequency conversion of KFR-7001LW / BP