Intelligence sits implement common breakdown intelligence sits implement breakdown maintains a method
Closestool is the indispensable establishment in the life, use for long, hard to avoid can appear problem of a few maintenance, the common problem that closestool maintains says for me:
1, closestool jams: Strong water insufficient or fall into eyewinker or ageing to be able to cause closestool jam, the method of dredge closestool has a lot of, come up against pliable other people to jam, use simple dredge tool to be able to be solved commonly. Good thing jams general need ravels closestool dredge.
2, closestool is slack: Ageing of closestool cistern fittings or attaint are out of order, it is commonly float or next water seal cover give an issue easily. It is OK to change.
3, closestool installs a problem: Vitreous glue or cement are used when bottom is installed, the screw aperture of dead closestool bottom is not sealed when installation.
4, closestool pushbutton is out of order: The commonnest is double pushbutton, pushbutton is out of order change it is OK to change directly.
4. intelligence implement breakdown phenomenon: Water is not hot (other is normal)
Check a part (remote controller, cistern heats canal, water lukewarm sensor, heat up fusing silk, computer board)
Intelligence implement breakdown handles way: Is remote controller temperature installed whether normal temperature? Move await 10 minutes, if do not have heat, unplug please next measurement cistern adds a hot line value of two end block is 92 ohm to control about, measure again heat be in charge of two end to whether 92 ohm control resistor, if do not have a frit fracture of wire bad, measure temperature sensor the block of two end is worth (25K ~ 80K) it is normal to be, it is normal to be like a computer board is bad, if change cistern, it is normal to after changing, detect, if water heats all the time a computer board is bad should change together.
5. intelligence implement breakdown phenomenon: Wenbujia is hot (other is normal)
Check a part (remote controller, housing washer adds heater, temperature sensor, computer board, receive plug-in unit)
Intelligence implement breakdown handles way: With the remote controller the setting heats condition (move await 10 minutes) if not have,heat, unplug next housing washer add a hot line to measure value of two end block to be 960+/ please - 50 ohm are controlled, if do not have open a way of electric heat silk, if have,measure temperature sensor two end block is worth (5K ~ 15K) it is normal to be, whether to receive plug-in unit to contact good? It is normal to be like a computer board is bad. If change housing washer, it is normal to after changing, detect, if housing washer heats all the time a computer board is bad should change together.
6. intelligence implement breakdown phenomenon: Wind is warm not hot (other is normal)
Check a part: (stoving device, computer board)
Intelligence implement breakdown handles way: Measure casing of silk of stoving electric heat whether do two end have 89 + / - if 4 ohmic resistor do not have a stoving device bad, if have, confirm correct move hind measure by dry key add heater casing electrical outlet whether do two end have 220V voltage, if do not have voltage criterion computer board is bad. If trade stoving unit,should examine carefully computer board. Remarks: Because load is increased,the short circuit between the trough that be like report is answered sometimes and rotate speed slow down brings about open a way of casing of electric heat silk, also can bring about computer board D882 to scorch phenomenal happening, tell computer board and stoving device to change at the same time please in those days.
Intelligence implement common breakdown handles method no wonder above a few kinds, if oneself cannot be handled, can ask professional personage processing.