Compare with photograph of semifinished product room, clothbound repairs a room to be able to save many time and energy for owner, get so the favour of owner. As a result of cannot whole journey monitoring decorates a process, and often explode the quality presence issue that gives clothbound to build a house, this is meant when check and accept must more scrupulous. Clothbound room introduces for everybody in the round as far as possible below acceptable knowledge, the hope can help great master.
One, clothbound room is checked and accept need to know
1, check and accept a tool to want to take neat
The test pencil on the belt, rule, belt 2 photographs / the electrical outlet of indication switch of three-phase outlet and power source (Yi Ke of small desk lamp) , the thing such as small hammer and flashlight. Electrography (measure socket) , rule (quantity length, level) etc as far as possible all ready tool.
2, written record is very important
Certain and written record is relevant when test house problem, facilitate with development business or its client connection rectify and reform item.
3, test house notices detail
The microscope when test house, some detail problem is very easy and unwary, for instance of the window sealed perfect.
4, test house wants more than 3
Test house avoid by all means is anxious, look more, ask more, much record.
2, clothbound room key checks and accept a project
1, quality of clothbound room air is very important
Because essence of life decorates a room,development business buys used data, owner is right the quality of material cannot accuse. Accordingly, when making a room, the first thing should affirm owner namely air quality amounts to mark.
Above all, the data that must affirm development business is bought accords with national level, harmful material does not exceed mark;
Next, according to national level, after project complete, development business should ask authoritative orgnaization to undertake indoor environment detect, and must be issued to the person that buy a house detect report. Mark of active air quality be careful in one's conduct allows pair of formaldehyde, benzene, TVOC, radon and ammonia the set limit to in air undertook 5 kinds of main harmful material set strictly. Those who need an attention is, contain only " CMA " the reports ability is the country is approbated classics of the label is the most authoritative detect the report that the orgnaization detects, it is invalid otherwise. If develop business or property to cannot provide qualified report, regard a building as off quality.
2, take cover engineering wants clothbound house careful
Take cover engineering includes canalage to transform, circuit is transformed, condole top structure and toilet are waterproof project these projects. The data that owner uses to take cover engineering, the trend of the cloth canal of canalage, circuit, the place that still has functional sex electrical outlet does not know etc, because hand in,these projects are buried in wall body after the room. Compare to professional requirement in view of take cover engineering tall, if him consumer understands not quite, the friend that suggests to understand relevant knowledge please or professional personage are accompanied see a room.
(1) check and accept clothbound room canalage
Common building dish canalage is 3 kinds normally, tap water, hot water and in water. In water dispute drinking water, it is to collect the water that use, use strong commode commonly or irrigate a flower. Owner needs the water in knowing hot water is mixed to whether be had, and whether to receive wrong conduit. Check the place of water meter even, should be in the mouth giving water of kitchen or toilet. Additional, the material of conduit and life are direct and relevant, should be the eligible material that the country appoints certainly. If conduit material is too poor, later period is very easy and slack.
(2) check and accept clothbound room circuit
Circuit is to show the position of socket is mixed match, the capacity of the model of electrical wiring and equipment of phone of the biggest bad news. This need owner runs a company to the property that is in a village or development business asks for the complete blueprint of the layout of take cover engineering such as basic water, report. Whether does the switch of protection of leakage of electricity that notices to survey distribution case even additionally have illume; average electrical outlet, high-power electrical outlet to wait have clear shunt, the installation of face plate switch whether level off, in the meantime, check switch even effective.
(3) check and accept top of clothbound room condole
A string of 1 very structure does not show on complete blueprint, but the flank of clothbound room, lamp or the intake of central air conditioning can see a structure. The observation mouth that owner carries on the head from condole is OK naked eye judgement, acceptable moment, basically examine what condole supports to have sex place whether crackle, craze, aperture waits.
(4) those who check and accept clothbound room is waterproof
Clear water falls to experiment in the toilet, kitchen space area that has waterproof demand, check enter the water whether unobstructed. If the floor drain of the nadir cannot have seeper, each enter the water place should running water unobstructed.
3, clothbound room checks and accept detail
Besides above of the greater respect that a few influences live outside checking and accept, problem of a few detail also can reflect what clothbound sends to decorate construction level very much. Owner is OK from a few more the following the place inspects a building decorate quality.
1, metope coating examination
Metope should be used be able to bear or endure water be bored with child, the besmear of wall paint is brushed should even, paint film is consistent.
2, examination of wall floor tile
Color is consistent. Range estimation is OK, generally speaking if have apparent problem, development business is in acceptable moment won't be passed. With floor tile of little weight knock and wall brick, if have empty voice, explain ceramic tile was not spread good, time became long may appear ceramic tile craze and fall off. Empty beat rate exceeds 5% to be able to be sentenced for unqualified.
3, examination hutch defends appliance
The switch of experiment faucet is effective, include to develop basin of room of water closestool, shower, face. Additional, need examination enters the water whether unobstructed, can go to in the spot crock of basin of the pool that wash dish, face, bath puts full water, discharge next go out, when check looks up what catchment speed; checks closestool to enter the water, want to undertake catchment experiments for many times repeatedly, see catchment effect.
4, installation of inspection door window
The push-pull that use a hand opens the door, switch of examination bedroom door is smooth, door lock hinge is effective window of; room external door closes especially the door window of the balcony is sealed eligible, open is agile.
5, equipment of examination central heating
Owner is detecting when central heating, should see pipeline expedite, temperature whether up to mark, whether to put in slack phenomenon.
6, inspect ventilated facility
Test platoon a place with a draught is smooth, kitchen and toilet check an air-valve even effective. If him kitchen always has the flavour that others home waves or toilet to peculiar smell flows backward, the likelihood answered air-valve to be out of order namely.
7, verify building materials model
All sorts of main data that clothbound compiles building project to use should be accurate between the contract without indicate by accident, especially the brand contains the device with taller Troy, if wholesome clean is provided, hardware of lamps and lanterns, galley equipment, furniture, clean provides hardware, and those who have function of guard against theft, fire prevention, sound insulation is muti_function the; such as the door besides the brand, still need to make clear the model of equipment, the equipment that some and producing area concern still should make clear producing area. Owner wants to contrast one by one with configuration sheet when test house, avoid to be moved to wrap by inferior product, reduce the class that decorate.